SUMMARY OF TESTS PERFORMED ON THE SAFETY BOOT®

Performed for SAFETY MAKER,INC. by STRESS ENGINEERING SERVICES - Houston, Texas.

TEST / TEMP

LAG BOLT

FENDER WASHER

SUBFLOOR MATERIAL

MAX. FORCE LBS.

1: Room
3/8" X 3"
3/8" X 1-1/4"

23/32" Sturd-I-Floor® Plywood &
2" X 10" Yellow Pine

488
2: Room
3/8" X 3"
3/8" X 1-1/4"
23/32" Sturd-I-Floor® Plywood &
2" X 10" Yellow Pine
502
3: Room
3/8" X 3"
3/8" X 1-1/4"
23/32" Sturd-I-Floor® Plywood &
2" X 10" Yellow Pine
467
4: 0 F
3/8" X 3"
3/8" X 1-1/4"
23/32" Sturd-I-Floor® Plywood &
2" X 10" Yellow Pine
680
5: -13 F
3/8" X 3"
3/8" X 1-1/4"
23/32" Sturd-I-Floor® Plywood &
2" X 10" Yellow Pine
574
6: -15 F
3/8" X 3"
3/8" X 1-1/4"
23/32" Sturd-I-Floor® Plywood &
2" X 10" Yellow Pine
542
7: Room
3/8" X 2"
3/8" X 1-1/4"
2" X 10" Yellow Pine
420
8: Room
3/8" X 2"
3/8" X 1-1/4"
2" X 10" Yellow Pine
407
9: Room
3/8" X 2"
3/8" X 1-1/4"
2" X 10" Yellow Pine
435
10: Room
3/8" X 2"
3/8" X 1-1/2"
2" X 10" Yellow Pine
337
11: Room
3/8" X 2"
3/8" X 1-1/2"
2" X 10" Yellow Pine
405
12: Room
3/8" X 2"
3/8" X 1-1/2"
2" X 10" Yellow Pine
430
13: Room
3/8" X 2"
3/8" X 1-1/2"
1-1/8" Sturd-I-Floor® Plywood
387
14: Room
3/8" X 2"
3/8" X 1-1/2"
1-1/8" Sturd-I-Floor® Plywood
530
15: Room
3/8" X 2"
3/8" X 1-1/2"
1-1/8" Sturd-I-Floor® Plywood
504